- Description
Description
Features
- Forged from High Tensile Alloy Steel
- Tempered
- 100% electromagnetic crack testing to AS1171
- Hi-Visibililty Powder Coating to AS4506
Specifications
Metric Course
Size A (mm) | WLL F1 (t) | WLL F2 (t) | B1 | B2 | C | D | E | G | H | I | K | A/F | Weight (kg |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 1 | 0.3 | 33 | 30 | 30 | 11 | 43 | 11 | 18.5 | 18 | 55 | 16 | 0.23 |
10 | 1 | 0.4 | 33 | 30 | 30 | 11 | 43 | 11 | 18.5 | 18 | 55 | 16 | 0.23 |
12 | 2 | 0.75 | 30 | 30 | 30 | 11 | 43 | 11 | 18.5 | 18 | 55 | 16 | 0.23 |
16 | 4 | 1.5 | 39 | 35 | 34 | 14 | 49 | 14 | 21.0 | 22 | 64 | 18 | 0.38 |
20 | 6 | 2.3 | 48 | 42 | 39 | 16 | 56 | 16 | 25.0 | 28 | 69 | 24 | 0.60 |
22 | 7 | 2.3 | 48 | 42 | 39 | 16 | 56 | 16 | 28.0 | 28 | 69 | 24 | 0.72 |
24 | 8 | 3.2 | 56 | 50 | 50 | 19 | 71 | 19 | 28.0 | 33 | 86 | 27 | 1.10 |
WLL (WORKING LOAD LIMIT)
Each Eyenut is clearly stamped with the permitted F2 WLL.
F2 WLL – indicates safe use for non-axial lifts.
F1 WLL – indicates loads which are in line with the axis of the threaded end of the eyenut. F1 WLL allows up to four (4) times higher lifting capacity whilst maintaining a 4:1 design factor of safety.